Specifically Detect and Quantify Myocardial Injury

When you suspect cardiac damage, get a definitive answer. This quantitative test measures cardiac Troponin I (cTnI), the gold-standard biomarker for heart muscle injury in dogs and cats.

Myocardial Injury
Cardiac Specific
Whole Blood/Serum/Plasma
Sample Type
5-10 Minutes
Time to Result
10 Kits/Box
Kit Size

The Tashikin cTnI Test provides a rapid and quantitative measurement of cardiac troponin I, a protein released exclusively from damaged heart muscle cells (myocytes). Unlike ECG or imaging, which assess function and structure, cTnI provides a direct biochemical marker of active injury. This makes it an invaluable tool for diagnosing conditions like myocarditis, assessing cardiac damage from trauma or GDV, and monitoring patients with chronic heart disease.

Your Path to a Clear Cardiac Assessment:

1

Investigate Acute Events

Use for emergency cases like blunt-force trauma, heatstroke, or GDV to assess the extent of secondary cardiac injury.

2

Diagnose Myocarditis

A significantly elevated cTnI in a patient with compatible clinical signs is a strong indicator of active myocardial inflammation.

3

Monitor Chronic Disease

Serial measurement of cTnI can help stage diseases like hypertrophic cardiomyopathy (HCM) in cats and monitor for ongoing myocardial damage.

Paraméter Érték
Analyte Cardiac Troponin I (cTnI)
Methodology Fluorescence Immunoassay (FIA)
Detection Range 0.1 - 10.0 ng/mL
Sample Type Canine & Feline Whole Blood, Serum, or Plasma
Sample Volume 100 µL
Assay Time 5-10 minutes
Kit Size 10 Tests / Kit
Storage 2-30°C (36-86°F)
Shelf Life 24 months from date of manufacture
92.5%
Relatív érzékenység
95.5%
Relatív specificitás
>99.0%
Relatív pontosság

Performance validated against established chemiluminescent immunoassays, ensuring high correlation for clinical decision-making.

1

Prepare Sample

Collect whole blood, or prepare serum/plasma, from the patient according to standard laboratory procedures.

2

Add Sample

Using a micropipette, add exactly 100µL of the prepared sample into the sample well of the test cassette.

3

Add Buffer

Add 2 drops of the provided assay buffer into the same well and start the timer immediately.

4

Read Result

At 10 minutes, insert the cassette into the Tashikin FIA Analyzer to obtain the quantitative cTnI concentration.

Trend Cardiac Biomarkers for Proactive Management

In chronic heart disease, the trajectory of cTnI can be more important than a single value. Logging serial results in VetEx.ai allows you to visualize the progression of myocardial injury over time, enabling more proactive management and clearer communication with clients about their pet's condition.